Blower

Side Channel Blower - Single Stage :

Pressure applications

Vacuum applications

RESSURE / FLOW VALUES (m³/h)

BLOWER CODE
POWER
UNIT
0 mbar
50 mbar
100 mbar
150 mbar
200 mbar
250 mbar
300 mbar
350 mbar
400 mbar
450 mbar
EJ 2 KB
0.25
kW
100
40
EJ 3 KB
0.55
kW
160
75
35
EJ 4 KB
0.75
kW
210
130
80
EJ 4 KB
1.1
kW
250
135
85
30
EJ 4 KB
1.5
kW
250
135
85
30
EJ 6 KB
2.2
kW
320
210
160
130
75
EJ 7 KB
3
kW
400
300
270
200
170
100
EJ 9 KB
4
kW
470
330
300
230
180
110
80
30
EJ 10 KB
5.5
kW
650
580
500
420
350
280
200
130
90
50
EJ 11 KB
7.5
kW
1050
920
800
700
570
310
180
80
EJ 12 KB
15
kW
1550
1400
1260
1140
1000
710
400
220
100

VACUUM / FLOW VALUES (m³/h)

BLOWER CODE
POWER
UNIT
0 mbar
25 mbar
50 mbar
75 mbar
100 mbar
125 mbar
150 mbar
175 mbar
200 mbar
225 mbar
250 mbar
EJ 2 KB
0.25
kW
100
55
EJ 3 KB
0.55
kW
160
120
75
40
EJ 4 KB
0.75
kW
210
160
120
80
60
EJ 4 KB
1.1
kW
250
180
125
90
70
20
EJ 4 KB
1.5
kW
250
180
130
95
75
25
EJ 6 KB
2.2
kW
370
225
180
160
100
55
EJ 7 KB
3
kW
400
340
300
280
260
220
180
140
100
EJ 9 KB
4
kW
470
400
330
305
290
250
220
140
80
EJ 10 KB
5.5
kW
650
590
540
490
450
390
340
290
250
170
100
EJ 11 KB
7.5
kW
1050
970
900
800
700
570
450
220
EJ 12 KB
15
kW
1550
1450
1380
1270
1170
1030
900
740
600
350

side Channel Blower - Double Stage :

Pressure applications

Vacuum applications

PRESSURE / FLOW VALUES (m3/h)

BLOWER CODE
POWER
UNIT
0 mbar
50 mbar
100 mbar
150 mbar
200 mbar
250 mbar
300 mbar
400 mbar
500 mbar
600 mbar
700 mbar
800 mbar
900 mbar
1000 mbar
EJ 5 KBZ
1.5
kW
250
175
140
110
75
60
30
EJ 6 KBZ
2.2
kW
250
190
150
120
90
70
70
70
70
40
EJ 7 KBZ
4
kW
320
280
250
230
200
175
150
100
60
EJ 9 KBZ
5.5
kW
360
300
260
240
220
190
160
110
70
EJ 9 KBZ
7.5
kW
380
320
280
265
250
225
200
160
140
110
80
40
EJ 9 KBZ
11
kW
410
350
310
290
280
265
250
200
170
140
110
70
EJ 10 KBZ
11
kW
700
650
600
550
500
470
430
350
300
250
180
120
50
EJ 11 KBZ
15
kW
1000
940
880
830
740
700
630
570
500
350
200
100
EJ 11 KBZ
18.5
kW
1050
950
900
850
800
750
660
600
520
400
300
250
190
120
EJ 12 KBZ
22
kW
1700
1580
1480
1420
1370
1320
1280
1160
990
780
540
350
100

VACUUM / FLOW VALUES (m3/h)

BLOWER CODE
POWER
UNIT
0 mbar
50 mbar
100 mbar
150 mbar
200 mbar
250 mbar
300 mbar
350 mbar
400 mbar
450 mbar
500 mbar
550 mbar
600 mbar
EJ 5 KBZ
1.5
kW
220
175
125
75
10
EJ 6 KBZ
2.2
kW
250
180
150
120
75
25
EJ 7 KBZ
4
kW
320
280
250
230
200
150
100
30
EJ 9 KBZ
5.5
kW
360
280
250
225
190
150
90
10
EJ 9 KBZ
7.5
kW
380
320
280
265
250
190
140
90
60
EJ 9 KBZ
11
kW
410
350
310
290
280
265
230
180
125
20
EJ 10 KBZ
11
kW
700
650
600
550
500
460
400
320
200
25
EJ 11 KBZ
15
kW
1000
940
880
830
740
700
580
410
210
10
EJ 11 KBZ
18.5
kW
1050
950
900
850
800
750
660
600
500
400
EJ 12 KBZ
22
kW
1700
1580
1480
1420
1300
1200
1100
900
600
300

Atex Blower - Single Stage :

Pressure applications

Vacuum applications

Pressure / Flow Values (m3/h)

S.NO
Blower Code
Power
Unit
0 mbar
50 mbar
100 mbar
150 mbar
200 mbar
250 mbar
300 mbar
350 mbar
400 mbar
450 mbar
1
EJ2-KB
0.25
kW
100
40
2
EJ3-KB
0.55
kW
160
75
3
EJ4-KB
0.75
kW
210
130
4
EJ4-KB
1.1
kW
250
135
5
EJ4-KB
1.5
kW
250
135
6
EJ6-KB
2.2
kW
320
210
7
EJ7-KB
3.0
kW
400
300
8
EJ9-KB
4.0
kW
470
330
9
EJ10-KB
5.5
kW
650
580
500
420
350
280
200
130
90
50
10
EJ11-KB
7.5
kW
1050
920
800
700
570
310
180
80
11
EJ12-KB
15
kW
1550
1400
1260
1140
1000
710
400
220
100

Atex Blower - Double Stage :